Sabre elsa service manual. 3M Scott Fire & Safety 2019-02-12

Sabre elsa service manual Rating: 7,3/10 853 reviews

Sabre Elsa 10 Minute Escape Set

sabre elsa service manual

Apparater der ikke passèrer samtlige kontrolpunkter, skal tages ud af funktion omgående og indleveres til reperation. The quick-fire strap can be used to pull the firing pin in the unlikely event of the pin not releasing when the bag is opened. Plomben brydes ved åbning af bæretasken, eller hvis der pilles ved apparatet. A sealed foam pad on the inner rear of the hood holds the hood in place when the wearer s head moves. If the firing pin is still in place, pull the yellow belt to free the pin.

Next

Sabre Safety ELSA

sabre elsa service manual

Denne test m√• kun udf√łres af personale, som har fuldf√łrt et formelt tr√¶ningskursus og er i besiddelse af et g√¶ldende certifikat for at kunne udf√łre reparations- og servicearbejde p√• flugtudstyr, der er fremstillet af Scott Health and Safety Limited. B√¶retasken kan ogs√• leveres i en antistatisk udgave sort. Den typ av skydd f√∂r andningsv√§garna som beh√∂vs. V√¶r opm√¶rksom p√• flugtapparatets begr√¶nsninger. Sabre the sabre logo design and names of sabre products are trademarks and or service marks of an affiliate of sabre inc all other trademarks service marks and trade names are owned by sds test tool users manual 15 26 connection to sabre the sds test tool connects to the sabre host automatically when it runs if the. G√∂r Dig v√§l bekant med planerade flyktv√§gar.

Next

ELSA. Compressed Air Escape Breathing Apparatus. User Instructions... 1 Brugervejledning Användarhandbok Bruksanvisning...

sabre elsa service manual

Air immediately flows into the hood. Apparatus held ready for use in a central store must be checked monthly. Lär Dig att använda flyktapparaten, se informationen i dessa instruktioner. Kontakta Utbildning och Teknisk Support eller Din lokale Sabre återförsäljare för information om utbildningskurser. Gå inte in i ett farligt område om inte Din flyktväg går genom det.

Next

Sabre Elsa Service Repair And User Owner Manuals PDF Book

sabre elsa service manual

Kontroll√®r at luftstr√łmmen er j√¶vn og rigelig. The spring-loaded exhale valve helps maintain an above ambient pressure within the hood. Manometeret orange felt indikerer det minimale tryk. When the cylinder is almost empty the warning whistle sounds. Den orange sektorn visar den minsta flaskfyllning som ger den angivna aktionstiden. Hold the hood with the neck seal over the crown of the head and pull the hood down over the head until the neck seal is around the neck. G√• ikke ind i et fareomr√•de, medmindre det er en del af flugtvejen.

Next

ELSA EEBD

sabre elsa service manual

Hols fast i b√¶retasken og tr√¶k toppen af. National regulations for compressed air breathing apparatus must be observed. Your Sabre distributor or Training and Technical Support Services will be pleased to provide training course details and quotes for service contracts. Fold h√¶tten ned i tasken og f√łr luftslangen ned under h√¶ttens bagerste del, s√• den ikke h√¶nger fast og l√•ser, n√•r h√¶tten tr√¶kkes ud af tasken. Listen for air flowing into the hood. Contaminants must be kept to a minimum, and must not exceed permissible exposure levels.

Next

Sabre Escape set ELSA EEBD

sabre elsa service manual

Check that there is a steady flow of air into the hood. Om utlösningssprinten mot förmodan inte frigörs när väskan öppnas kan aktiveringsbandet användas för att dra ut den. Once the apparatus has been used it must be returned to be serviced and have the cylinder re-charged. Træk lufthætten ud af bæretasken. Fluid must not enter the inner mask. The apparatus has been used.

Next

Sabre Elsa Service Repair And User Owner Manuals PDF Book

sabre elsa service manual

Det finns flyktv√§gar som kr√§ver h√•rd fysisk anstr√§ngning som exempelvis stegar, tunnlar och luckor. Flugtapparatet kan suppleres med et b√¶lte, for bedre at fastg√łre flugtapparatet til brugeren, og derved give st√łrre bev√¶gelsesfrihed. Fold hood into bag and arrange the breathing hose under the rear of the hood so that it will not foul when the hood is pulled from the bag. This test must only be carried out by personnel who have completed a formal training course and hold a current certificate for the servicing and repair of escape equipment manufactured by Scott Health and Safety Limited. Do not roll or fold the neck seal when donning the hood. Plomberingen √§r intakt i det fall s√•dan anv√§ndes. Se ovan f√∂r adress etc.

Next

Sabre Elsa Service Repair And User Owner Manuals PDF Book

sabre elsa service manual

Check that access to the bag is unobstructed. Close the compressor supply valve, bleed off pressure from the supply hose, disconnect the charging adaptor from the cylinder and fit the charging adaptor dust cover. The warning whistle sounds when the designed duration 10 or 15 minutes. √Öbn tasken helt og kontroll√®r at splitten sidder korrekt. Remove the charging adaptor dust cover and store safely for use later. A waist belt, which prevents the bag swinging while in use, is available as an option for all versions of the bag. Er rem-men fastgjort, √•bnes ventilen automatisk n√•r b√¶retaskens top l√łftes, og der vil str√łmme luft til h√¶tten.

Next